SaveNXSPE now stores the run number of the input workspace in the instrument section.
For Indirect instruments it also saves
efixed, taken from the detector’s crystal analyzer properties. If all crystal analyzers have the same energy, a singleefixedis written intoNXSPE_info->fixed_energyas before, while if detectors have different analyzer energies, an array of the energies is written into theNXSPE_info->fixed_energyfield of the.nxspefile. Also for Indirect instruments, nofermifield is added to theinstrumentfolder. The algorithm has also been modified so ifEiis provided as the propery value it always overrides the values retrieved from the workspace.
Bugfixes¶
ALFView no longer crashs when moving the cursor over the Instrument View while loading data.
ALFView no longer crashes when closing the interface while it is loading data.
PyChop no longer uses random phase values on Merlin when instrument scientist mode disabled.
Fix for incorrect incident energies for
MERLINin PyChop when not in instrument scientist mode.
MSlice¶
New features¶
Noneis now a new line style option. With this feature, it is possible to plot error bars without including a line.The spectrum ID is no longer printed when saving a 2D workspace as an ASCII file.
Bugfixes¶
The
Intensitymenu on slice plots is now disabled in interactive mode to prevent crashes.Bug fix implemented to save cut data in a 3-column file instead of a single line.
CrystalField¶
Bugfixes¶
The method
cf.getMagneticMoment()no longer ignores theHmagfield, which is now correctly considered in the calculations of the magnetic moment.