Reconstruction Window

The reconstruction window contains the tools for center of rotation (COR) and tilt alignment, beam hardening correction (BHC) and tomographic reconstruction.

Operations dialog

The main part of the window shows the currently selected stack in projection and sinogram space and a preview reconstruction of the currently selected slice. The slice can be selected by clicking in the projection view or using the controls in the Preview section.

Previews are automatically updated when parameters are changed. For reconstructions that take a long time to run, such as iterative algorithms, it is worthwhile to disable the Auto Update option and trigger preview updates manually using the Update Now button.

COR and Tilt

Is described in the section Center of Rotation and Tilt

Beam Hardening Correction

Mantid Imaging implements a linearization correction to compensate for the beam hardening effect. This is applied to the projection pixel values before being passed to the reconstruction algorithm. First we convert from transmission to line density as normal:

\[s = -log(I)\]

then a polynomial correction is applied:

\[s' = s + a_0\, s^2 + a_1\, s^3 + a_2\, s^4 + a_3\, s^5\]

The coefficients \(a_0, a_1, a_2, a_3\) can be input by the user on the BHC tab in the reconstruction window.